Flat wiping contact system Minimal contact resistance at high current, wiping action cleans contact surface during connection/disconnection
Mechanical keyed housings Prevents accidental mating of components operating at different voltage levels
Water proof Connector pair inserted to waterproofing level IP67
Ergonomic design Is “user friendly” during connection and disconnection of the system
Lock catch Self-locking function with secondary reinforcement lock
Docking Board to Line and Line to Line
PSF90 SERIES (2 POWERS + 4 SIGNAL CONTACTS)
RECOMMENDED PANEL CUTOUT (mm)
POWER CONTACTS
MALE SIGNAL CONTACTS
FEMALE SIGNAL CONTACTS
PSF90 HOUSING SPARE PARTS
PSF90 HOUSING SPARE PARTS
PSF90 CONNECTOR ASSEMBLY
Either power cables and signal wires must be inserted thru Rear Cover (8) and “Terminal Wire Ring” (7)
Strip cables and wires-crimp either Power Contact (5) and Signal Contacts (12-6)
Insert Power Contacts according positive and negative polarity indicated on Connector Housing Male (2) or Female (9)
Insert Male Signal Contacts into Holder (11) positioned into Female Housing (9) and female Signal Contacts into Holder (1) positioned into Male Housing (2) then push Terminal Wire Ring (7) and lock Rear Cover (8)
PSF90 CONNECTOR DISASSEMBLY
Either Rear Cover (8) and “Terminal Wire Ring” (7) must be pulled back along cables and wires
To remove Power Contacts simply with a small screw driver pushing down retaining springs and pull cables
To remove Signal Contacts it is necessary to extract Holders (1 or 11) from housing male or female using special tools (see “Tooling” section). To insert tool from front for female housing and rear for male one then to pull signal wires or using a little pincer. In case of “Repair” it is necessary to replace Holder and contacts
TOOLING
Crimping tool for Signal Contacts: Cat. Nr. W2D
To remove Holder (11) from female Housing (9) use: Cat. Nr. 28×10002
To remove Holder (1) from male Housing (2) use: Cat. Nr. 28×10001