Grid Power PSF90

grid-power-connectors

PSF90 SERIES WATERPROOF CONNECTORS

PRODUCTS FEATURES

Flat wiping contact system
Minimal contact resistance at high current, wiping action cleans
contact surface during connection/disconnection

Mechanical keyed housings
Prevents accidental mating of components operating at different
voltage levels

Water proof
Connector pair inserted to waterproofing level IP67

Ergonomic design
Is “user friendly” during connection and disconnection
of the system

Lock catch
Self-locking function with secondary reinforcement lock

Docking
Board to Line and Line to Line

grid-power-psf90

PSF90 SERIES (2 POWERS + 4 SIGNAL CONTACTS)

RECOMMENDED PANEL CUTOUT (mm)

POWER CONTACTS

MALE SIGNAL CONTACTS

FEMALE SIGNAL CONTACTS

PSF90 HOUSING SPARE PARTS

PSF90 HOUSING SPARE PARTS

PSF90 CONNECTOR ASSEMBLY

  1. Either power cables and signal wires must be inserted thru Rear Cover (8) and “Terminal Wire Ring” (7)
  2. Strip cables and wires-crimp either Power Contact (5) and Signal Contacts (12-6)
  3. Insert Power Contacts according positive and negative polarity indicated on Connector Housing Male (2)
    or Female (9)
  4. Insert Male Signal Contacts into Holder (11) positioned into Female Housing (9) and female Signal Contacts
    into Holder (1) positioned into Male Housing (2) then push Terminal Wire Ring (7) and lock Rear Cover (8)

PSF90 CONNECTOR DISASSEMBLY

  1. Either Rear Cover (8) and “Terminal Wire Ring” (7) must be pulled back along cables and wires
  2. To remove Power Contacts simply with a small screw driver pushing down retaining springs and pull cables
  3. To remove Signal Contacts it is necessary to extract Holders (1 or 11) from housing male or female using special
    tools (see “Tooling” section). To insert tool from front for female housing and rear for male one then to pull signal
    wires or using a little pincer. In case of “Repair” it is necessary to replace Holder and contacts

TOOLING

Crimping tool for Signal Contacts: Cat. Nr. W2D

To remove Holder (11) from female Housing (9)
use: Cat. Nr. 28×10002

To remove Holder (1) from male Housing (2)
use: Cat. Nr. 28×10001